Physical background

How two perpendicular oscillations create Lissajous figures, and why an electron beam leaves a glowing trace on a phosphor screen.

1. What glows on the screen

In an analogue oscilloscope, a focused electron beam strikes a phosphor coating. The spot it hits lights up. Two deflection systems move this spot horizontally and vertically. In XY mode, two electrical signals control these directions independently.

DR.Lissajous shows this landing spot on a simulated phosphor screen. The bright dot is not an individual electron. The visible trace consists of successively excited parts of the phosphor, not an electron travelling across the glass. The electrons travel towards the screen inside the tube.

2. Two oscillations, one movement

Both deflection signals are sinusoidal. With constant settings since a common start:

x(t) = Ax · sin(2π · fx · t)
y(t) = Ay · sin(2π · fy · t + φ)

x and y are the displacements from the centre. Right and up are positive. The amplitudes Ax and Ay set the greatest displacement and range from 0 to 100%. Here, 100% is the intended maximum deflection for that channel. The grid provides orientation and is not a calibrated voltage scale.

The frequencies fx and fy range from 0 to 1 Hz. One hertz means one complete oscillation per second. At 0.2 Hz, each oscillation takes five seconds. This slow timescale makes the formation of the figure visible.

The additional phase φ shifts the vertical oscillation relative to its underlying phase. The control displays degrees from 0° to 360°. In the equation, 180° corresponds to π radians. With different frequencies, the instantaneous phase difference changes as time passes.

3. Lines, ellipses and interwoven figures

With equal frequencies and a phase offset of 0°, both displacements change together and produce a straight line. At 180°, it slopes the other way. A 90° offset produces a circle when the amplitudes are equal, or an ellipse when they differ.

Different frequencies produce interwoven Lissajous figures. For example, with a frequency ratio of 2 : 3, the horizontal signal completes two oscillations while the vertical signal completes three. After their common period, both motions return together and the figure closes.

Try 0.2 Hz and 0.3 Hz. Their common period is ten seconds. At 0.2 Hz and 0.21 Hz, a complete repetition instead takes one hundred seconds. A short afterglow therefore does not always show the entire figure yet.

These phase examples refer to a common start of the oscillations. After different frequency adjustments, both channels also retain the phases accumulated along the way. Resetting restores their common starting point.

4. What the controls change

The sliders specify target values. You can also enter a target directly in the number field. After you confirm the entry, the field returns to showing the currently effective value and visibly follows its change. The target also appears below the slider during the transition. The effective settings move continuously towards it, even after a large numeric entry. Amplitudes change at ten percentage points per second, the additional phase at ten degrees per second and frequencies at 0.1 Hz per second. Once a target is reached, the setting stays there. Changing the target during a transition starts from the currently effective setting.

The ongoing carrier phases are preserved when frequency changes. The calculation accounts for the effective frequency throughout the transition. The beam therefore does not jump to another point, and time does not restart. At 0 Hz, that channel’s carrier phase stops advancing. Adjusting its amplitude or the additional phase can still change the landing spot.

Amplitude and phase adjustments also change the deflection continuously. A phase adjustment in progress moves the luminous spot in addition to its underlying oscillation. The phase control traverses the selected numeric range: going from 0° to 360° passes through every intermediate angle, although its start and end represent the same phase.

Parts of the screen that already glow retain their trace when you adjust the controls. In “Afterglow” mode, the old trace gradually fades. In “Permanent” mode, it stays visible. This lets you observe how the figure changes during an adjustment.

“Clear trace” removes only the image and changes neither the oscillations nor time. “Reset” deliberately restarts the experiment and immediately restores the initial settings with equal amplitudes, equal frequencies and an additional phase of 90°.

5. Off, afterglow or permanent

Off shows the current glowing spot without a stored path. Afterglow lets previously excited parts of the screen gradually fade. The bright core and softer surrounding glow approximate the image of a focused electron beam on phosphor.

Permanent retains the drawn trace until you clear it, change mode or reset. This is an idealised storage view. Real phosphor would eventually fade without further excitation. The three modes change only the display, never the oscillations.

Switching mode starts a fresh trace. Pause freezes the underlying oscillations, simulation time and trace image. Settings still move continuously towards their targets. The current spot previews these adjustments without drawing a new trace. Switching to another browser tab also pauses the experiment. The oscillations continue only after you select “Resume”.

6. Calculation and model limits

The app advances each channel’s ongoing phase and evaluates its sine directly. During a linear frequency transition, the phase change follows from the average frequency and the transition duration. If a target is reached partway through a step, the remaining time uses that constant frequency. The final frequency is therefore not applied retrospectively to the entire step.

This does not require a stepwise approximation of a mechanical equation of motion. Oscillations follow elapsed simulation time, while settings follow their actual transition duration. Both are independent of the display refresh rate. Small intermediate steps keep the drawn trace smooth.

The model assumes ideal, linear deflection proportional to the corresponding signal. It does not calculate individual electrons, their acceleration, charge clouds, lens aberrations, electrical interference or the chemical processes in the phosphor. Reflections, the glowing spot and afterglow are visual approximations, not measurements of a particular tube.

Amplitudes are relative settings, not measured voltages. There is no calibrated beam brightness or energy balance. The permanent trace is an image buffer, not an endlessly growing set of measurements. All calculations and traces remain in the browser.